All | Aerosol | Chemical | Clean | CO2 | Cold | Components | Cooking | EN | FM | Foam | Gas | Halon | Hybrid | Hydrants | Installation | ITM | Liquids | Mist | NFPA | Oxygen | Pipework | Powder | Pumps | Residential | Spark | Spray | Sprinkler | Supply | Tanks | VdS | Ventilation | Water |
Number | Title | Keywords |
---|---|---|
NFPA 12 | Standard on Carbon Dioxide Extinguishing Systems | CO2 |
NFPA 13 | Standard for the Installation of Sprinkler Systems | Water |
NFPA 13R | Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies | Water |
NFPA 14 | Standard for the Installation of Standpipe and Hose Systems | Water |
NFPA 15 | Standard for Water Spray Fixed Systems for Fire Protection | |
NFPA 16 | Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems | |
NFPA 17 | Standard for Dry Chemical Extinguishing Systems | |
NFPA 17A | Standard for Wet Chemical Extinguishing Systems | |
NFPA 22 | Standard for Water Tanks for Private Fire Protection | |
NFPA 25 | Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems | |
NFPA 96 | Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations | |
NFPA 291 | Recommended Practice for Water Flow Testing and Marking of Hydrants | Water |
NFPA 750 | Standard on Water Mist Fire Protection Systems | Water |
NFPA 770 | Standard on Hybrid (Water and Inert Gas) Fire-Extinguishing Systems | |
NFPA 2001 | Standard on Clean Agent Fire Extinguishing Systems | Gas |
NFPA 2010 | Standard for Fixed Aerosol Fire-Extinguishing Systems | |
EN 12845 | Fixed firefighting systems - Automatic sprinkler systems | Water |
EN 12259 | Fixed firefighting systems - Components for sprinkler and water spray systems | |
EN 16925 | Fixed firefighting systems - Automatic residential sprinkler systems | Water |
EN 14972 | Fixed firefighting systems - Water mist systems | |
EN 17450 | Fixed firefighting systems - Water mist components | |
EN 15004 | Fixed firefighting systems - Gas extinguishing systems | |
EN 12094 | Fixed firefighting systems - Components for gas extinguishing systems | |
EN 16750 | Fixed firefighting systems - Oxygen reduction systems | |
EN 15276 | Fixed firefighting systems - Condensed aerosol extinguishing systems | |
EN 12416 | Fixed firefighting systems - Powder systems | |
EN 13565 | Fixed firefighting systems - Foam systems | |
CEN/TS 14816 | Fixed firefighting systems - Water spray systems | |
EN 671 | Fixed firefighting systems - Hose systems | Hydrant |
EN 17446 | Fire extinguishing systems in commercial kitchens | Cooking |
VdS 2093 | CO2 Fire Extinguishing Systems, Planning and Installation | ITM |
VdS 2100 | Wet Alarm Valve Stations, Requirements and Test Methods | Water Sprinkler |
VdS 2108 | Guidelines for Foam Extinguishing Systems, Planning and Installation | |
Vds 2100 | Guidelines for Water Extinguishing Systems | |
VdS 2108 | Guidelines for Foam Extinguishing Systems, Planning and Installation | |
VdS 2109 | Guidelines for Water Spray Systems, Planning and Installation | |
VdS 2106 | Spark Detection, Spark Separation and Spark Extinguishing Systems, Planning and Installation | |
VdS 2132 | Guidelines for the Approval of Installer Companies of Fire Extinguishing Systems | Installation |
VdS 2369 | Anti-freeze solutions | Cold |
VdS 2377 | Sprinkler Systems Application Range | Water |
VdS 2380 | Fire Extinguishing Systems Using Non-liquefied Inert Gases, Planning and Installation | |
VdS 2381 | Fire Extinguishing Systems using Halocarbon Gases, Planning and Installation | |
VdS 2454 | Gas Extinguishing Systems, Requirements and Test Methods | |
VdS 2518 | Spark Extinguishing Systems | |
VdS 2557 | Planning and Installation of Facilities for Retention of Extinguishing Water | |
VdS 2562 | Procedure for the approval of new extinguishing techniques | |
VdS 2807 | Extinguishing Systems for the Protection of Equipment in Commercial Kitchens, Requirements and Test Methods | Cooking |
VdS 2815 | Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS), Fire Protection Leaflet | Ventilation |
VdS 2896 | Sprinkler Systems for Residential Occupancies | |
VdS 3100 | High Pressure Water Mist Systems, Requirements and Test Methods | |
VdS 3124 | Foam concentrates | |
VdS 3141 | Foam Concentrates in Fixed Extinguishing Systems | |
VdS 3188 | Guidelines for Water Mist Sprinkler Systems and Water Mist Extinguishing Systems (High Pressure Systems), Planning and Installation | |
VdS 3472 | Extinguishing water additive | Foam |
VdS 3518 | Safety and Health Protection in Connection with Gas Extinguishing Systems | |
VdS 3527 | Oxygen Reduction Systems, Planning and Installation | |
VdS 3843 | Use of pendant sprinklers in dry systems - Leaflet | Sprinkler Cold |
VdS 3859 | Design of Sprinkler Systems for the Protection of Flammable Liquids - Leaflet | |
VdS 3891 | Galvanised Pipework in Sprinkler Systems, VdS Data Sheet | |
VdS 3896 | Proof of Effectiveness for Foam Concentrates - Application Cases and Proof of Effectiveness for Foam Concentrates in Stationary Water Extinguishing Systems | |
VdS 4001 | Sprinkler Systems, Planning and Installation | Water |
VdS 4033 | Waterbased spark extinguishing devices in ducts, Requirements and Test Methods | |
FMDS 2-0 | Installation Guidelines for Automatic Sprinklers | Water |
FMDS 2-1 | Corrosion in Automatic Sprinkler Systems | Water |
FMDS 2-5 | Installation Guidelines for Automatic Sprinklers In Residential Occupancies | Water |
FMDS 2-8 | Earthquake Protection for Water-Based Fire Protection Systems | |
FMDS 2-10R | Dry Pipe, Deluge, Preaction Valves and Accessories | Water |
FMDS 2-81 | Fire Protection System Inspection, Testing and Maintenance | ITM |
FMDS 2-89 | Pipe Friction Loss Tables | Pipework |
FMDS 3-0 | Hydraulics of Fire Protection Systems | Water Pipework |
FMDS 3-1 | Tanks and Reservoirs for Interconnected Fire Service and Public | Water Supply |
FMDS 3-2 | Water Tanks for Fire Protection | Supply |
FMDS 3-3 | Cross Connections | Water Supply |
FMDS 3-4 | Embankment-Supported Fabric Tanks | Water Supply |
FMDS 3-6 | Lined Earth Reservoirs for Fire Protection | Water Tanks Supply |
FMDS 3-7 | Fire Protection Pumps | Supply |
FMDS 3-10 | Installation/Maintenance of Fire Service Mains and Their Appurtenances | Water Supply |
FMDS 3-11 | Flow and Pressure Regulating Devices for Fire Protection Service | Supply Components |
FMDS 3-26 | Fire Protection for Nonstorage Occupancies | Water Sprinklers |
FMDS 3-29 | Reliability of Fire Protection Water Supplies | Supply |
FMDS 4-0 | Special Protection Systems | |
FMDS 4-1N | Fixed Water Spray Systems for Fire Protection | |
FMDS 4-4N | Standpipe and Hose Systems | Hydrants |
FMDS 4-3N | Medium and High Expansion Foam Systems | |
FMDS 4-7N | Low Expansion Foam Systems | |
FMDS 4-9 | Halocarbon and Inert Gas (Clean Agent) Fire Extinguishing Systems | |
FMDS 4-13 | Oxygen Reduction Systems | |
FMDS 4-11N | Carbon Dioxide Extinguishing Systems | CO2 |
FMDS 4-2 | Water Mist Systems | |
FMDS 4-6 | Hybrid (Water and Inert Gas) Extinguishing Systems | |
FMDS 4-8N | Halon 1301 Extinguishing Systems | |
FMDS 4-10 | Dry Chemical Processing Systems | |
FMDS 4-12 | Foam Extinguishing Systems |